Automatic
Moisture Control System
MCSII
Continuous Measurement & Control of Wheat Moisture
Application:
Wheat

Features:
- Digital Dynamic
Weighing System
- Maximum Wheat Rate Measurement .....................................................14
t/h
- Maximum Water Rate Digital Measurement ........................................... 300
cc/sec
- Maximum Water Rate Display by Rotameter ......................................... 1000
L/h
- Water Rate Control Accuracy ............................................................... ± 1
cc/sec
- Input Wheat Moisture Measurement Accuracy ....................................... ±
0.5%
- Input Wheat Moisture Measurement Range ...........................................
8.5%-16%
- Output Wheat Moisture Control Range .................................................. up to 6% at
8.5%-20%
- Automatic
Water Shut Off in Case of No Wheat
Current
- Wheat/Water
Bypass Routes for Manual
Operation
- Eight
Control
Alarms
- Input
Wheat Sampling
Station
- Two
Separate Back up Routes for Water
Filteration
- Stainless
Steel & Polyethylene Water
Pipes
- Aspiration
System ( Dedusting
)
- Power Consumption
........................................................................... 220VAC 1PH
50Hz / 150
W